TROUBLESHOOTING HOME
TEMPERATURE  GAUGE TEST

-Check that there is power and ground at the gauge in the proper positions.

-Remove the  sender wire from the sender, hang loose so that the ring terminal does not touch ground.

-Turn on the key, gauge should peg low.

-Touch the sender wire end to ground> The gauge should peg high. 

-If it does not peg do the same test at the back of the gauge to rule out the wire.

Gauge pegs in either test> gauge good TEST SENDER

Gauge does not peg in either test call NVU tech support at 248-850-5482 please have the code AC-TEMP-1 available